Description – A succinct statement of the fault.
■
Response – A description of how the system responded to the failure.
■
Impact – A description of the consequences if no service action is taken.
■
Action – Additional tasks the user can do to supplement troubleshooting the fault.
■
This is an example of a power supply fault:
The characters SPT at the beginning of the message ID indicate that the fault was
Note -
detected by Oracle ILOM.
------------------- ------------------------------------ -------------- --------
Time
------------------- ------------------------------------ -------------- --------
2011-09-13/15:47:41 d7d67b9b-ba67-e257-8d8d-bcef2db2971b SPT-8000-MJ
Fault class : fault.chassis.power.fail
FRU
: /SYS/PS0
(Part Number: 300-2304)
(Serial Number: C40003)
Description : A Power Supply has failed and is not providing power to the
server.
Response
: The service required LED on the chassis and on the affected
Power Supply may be illuminated.
Impact
: Server will be powered down when there are insufficient
power supplies operational.
Action
: The administrator should review the ILOM event log for
additional information pertaining to this diagnosis. Please
refer to the Details section of the Knowledge Article for
additional information.
4.
(Optional) Display the fault history.
faultmgmtsp> fmdump
TIMESTAMP
2011-12-20/06:00:14 52db4790-1d30-e1d5-b4e3-8bf677246bd2
2011-12-20/06:03:26 52db4790-1d30-e1d5-b4e3-8bf677246bd2 ILOM-8000-30 Repaired
2011-12-20/06:03:26 52db4790-1d30-e1d5-b4e3-8bf677246bd2 ILOM-8000-30 Resolved
2012-01-27/18:47:27 f69cca33-4759-4e16-9a06-9feaaa19a15c
2012-02-16/16:54:08 f69cca33-4759-4e16-9a06-9feaaa19a15c SPX86-8003-K5 Repaired
2012-02-16/16:54:08 f69cca33-4759-4e16-9a06-9feaaa19a15c SPX86-8003-K5 Resolved
2012-03-06/20:13:05 63e1c3c7-910a-e825-83d5-d180378f54ae
2012-03-06/20:24:12 63e1c3c7-910a-e825-83d5-d180378f54ae SPX86-8003-73 Repaired
2012-03-06/20:24:13 63e1c3c7-910a-e825-83d5-d180378f54ae SPX86-8003-73 Resolved
faultmgmtsp>
UUID
UUID
Display Faults (faultmgmt Shell)
msgid
Severity
Critical
MSGID
ILOM-8000-30
SPX86-8003-K5
SPX86-8003-73
Detecting and Managing Faults
49
Need help?
Do you have a question about the netra X5-2 and is the answer not in the manual?