Camshaft Timing Oil Control Valve; Inspect Oil Control Valve Resistance - Toyota Celica 2000 Repair Manual

Hide thumbs Also See for Celica 2000:
Table of Contents

Advertisement

SF-46
1ZZ-FE:
SF!
CAMSHArT TIMING OIL CONTROL VALVE
CAMSHAFT TIMING OIL CONTROL
VALVE
ON-VEHICLE INSPECTION

INSPECT OIL CONTROL VALVE RESISTANCE

Remove the No. 2 cylinder head cover.
(a)
(b)
2ZZ-GE:
Disconnect the 2 PCV hoses.
Disconnect the oil control valve connector.
(c )
Using an ohmmeter, measure the resistance between the
(d)
terminals.
Resistance:
6.9 - 7.9 n at 2o·c (68.F)
If the resistance is not as specified, replace the valve.
Reconnect the oil control valve connector.
(e)
Reinstall the V-bank cover.
(f)

Advertisement