Self Diagnosis - SSANGYONG 1999 Musso Service Manual

Table of Contents

Advertisement

SELF DIAGNOSIS

ABS, ABS/ABD 5.3
Initialization
1. Turn the ignition switch to "ON" position.
2. Using a service connector, ground the No.13 terminal of
diagnosis socket and No.1 ground terminal for 3 - 4 seconds.
Notice
If it is over 5 seconds, initialization will not be performed.
3. After completing the initialization, ABS warning lamp will be
turned on until the ignition switch is turned to "OFF" position.
Output of Fault Code
1. Normal : 1 pulse (normal code 01)
2. Abnormal : 1 pulse (fault code)
Notice
If appeared initial fault code and above 2 differnt fault
code, perform again initialization.
Fault code will be output the numbers of fault code with
a interval of 1 second.(turn on : 0.75 sec., turn off : 0.25
sec.)
Fault Code Elimination
After repairing the defect parts, eliminate the fault from ECU.
1. Ground the diagnosis No.13 terminal to No.1 ground terminal
for over 5 seconds.
2. Turn the igniotion switch to "OFF" position.
Notice
If not eliminate the fault code, the code will be maintained.
Check and find the other defect parts with performing
the imitialization again, if the fault code will be output,
repair the defect parts completely.
ANTILOCK BRAKE SYSTEM 4F-9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents