Inspection & Maintenance (for E2.3 MSE)
1. Measure the primary resistance between the cable terminals
1 and 15 after removing the ignition cable wiring connector
(1 and 15) with ignition switch OFF.
Notice
Replace the ignition coil if out of the specified resistance.
Specified Value
2. Measure the primary voltage(T1/1) between the ECU
terminals No.72 and No.69 during the engine cranking
(starter motor activated).
Specified Value
T1/2 : between No.71 and No.69
Notice
Check the ignition cable and the ECU if out of the
specified value.
3. Measure the secondary cable resistance between the
ignition coil 5a and 5b using a multimeter.
Specified Value
0.9 - 1.6 W
200 - 350 V
6 - 8.5 KW
M161 ENGINE ELECTRICAL 1E2-11