9T-6 REMOTE KEYLESS ENTRY AND ANTI-THEFT SYSTEM
Input Memory
When the REKES transmitter is lost
1. Connect the battery terminal No.3 and REKES terminal No.4
which are on the diagnosis socket in engine room with service
lead wire.
2. Push the lock or unlock button on the REKES transmitter.
3. Input Memory and close all doors.
4. Check the operation of door locking system by pushing the
lock or unlock button on the REKES transmitter.
When the transmitter is faulty
1. Replace the REKES transmitter with a new one and connect
the wiring connector.
2. Set the input switch of the REKES receiver onto the No.1 or
No.2 position and push the lock or unlock button on the
REKES transmitter.
3. Set the input switch of the REKES receiver onto the central
position and close all doors.
4. Check the operation of door locking system by pushing the
lock or unlock button on the REKES transmitter.
1 REKES Transmitter
2 Input Switch of the REKES Receive
3 REKES Switch