ABS, ABS/ABD 5.0
Initializing
1. Set the ignition switch n "ON" position.
2. Connect the No.1 terminal (Ground) and the No.13 (ABS)
from diagnosis socket located in E/G room by use of service
connector for 3 - 4 seconds and initialize the flash code.
Notice
Be careful not to connect over 5 seconds.
3. ABS indicator warning light continuously comes on until the
ignition switch is "OFF".
Dignosis Table
1. When the system is normal
One pulse (normal code 01) indicates.
2. When the system is abnormal
One pulse (defect code) indicates.
Notice
Repeat the initializing procedure when checking the
defect code Defect code is indicated once for 1 sec (light
on : 0.75 sec, light off : 0.25 sec).
Removal the Defect Code
1. Repair the defect code and remove the memorized defect
code in the ECU.
2. Connect the No. 13 terminal (ABS) from diagnosis socket
and No. 1 terminal (ground) for over 5 seconds.
3. Set the ignition switch in the "OFF" position.
Notice
Defect code will be memorized in ECU unless the defect
code is not removed.
Repeat the initializing procedure and check the other
defects.