5A-92 AUTOMATIC TRANSMISSION
Planet Carrier and Centre Support
To remove the planet carrier and centre support, proceed as
follows.
1. Separate the planet carrier and centre support from the
output shaft. Remove the thrust bearings from the output
shaft and the planet carrier.
2. Separate the centre support from the planet carrier by
rotating it anti-clockwise.
3. Lift the one way clutch from the planet carrier.
4. Remove the circlip retaining the one way clutch outer race
in the planet carrier and remove the race.
5. Remove the one way clutch retainer from the planet carrier.
Pump
Note that the following valves are housed in the pump cover:
Solenoid 7
C1 bias valve
Converter clutch control valve
Converter clutch regulator valve
Primary regulator valve
To remove the pump, proceed as follows.
1. Remove the wiring loom retainer plate and remove
solenoid 7 with a T30 Torx bit.
2. Remove the five washer head bolts from the cover plate
using a multi-point 8 mm socket.
3. Remove the five Torx head screws from the cover plate
(Torx bit No. 30). Note that the odd screw holds the pump
body to the pump body cover.
Notice
Do not strike the converter support tube to loosen the
pump body.
4. Separate the pump body from the pump cover.
5. Lift the cover plate from the cover.
6. Remove the two ball check valves and one spring from
the pump cover.
Notice
Some of the valves and plugs are preloaded by springs
and may unexpectedly fall out of the cover when the pins
are removed.
7. Depress the plug inward and remove the retaining pin for
each of the four valves.
8. Remove the four valves, plugs and springs.
9. Remove the pump gears from the pump body.
10. Remove the lip seal from the front of the pump body.