Removing Accessible Drive Dummy Covers; Installing The 4X 3.5-Inch Hdd Extension Box; Cabling The Slimline Odd On The Hdd Extension Box - Fujitsu PRIMERGY TX300 S7 Upgrade And Maintenance Manual

Table of Contents

Advertisement

Accessible drives

12.7.1.4 Removing accessible drive dummy covers

Removing accessible drive filler covers
Ê Remove accessible drive filler covers from installation bays 1, 2 and 3 as
described in section
V
CAUTION!
Always replace filler covers into unused drive bays to comply with
applicable EMC regulations and satisfy cooling requirements.
Removing accessible drive covers
Ê Remove accessible drive covers from installation bays 1, 2 and 3 as
described in section

12.7.1.5 Installing the 4x 3.5-inch HDD extension box

Ê Prepare the accessible drive mounting brackets and install the 4x 3.5-inch
HDD extension box into installation bays 1, 2 and 3 as described in section
"Installing the 4x 3.5-inch HDD extension box" on page

12.7.1.6 Cabling the slimline ODD on the HDD extension box

I
For SAS cabling of HDD extension box backplanes, please refer to
section
"HDD extension boxes" on page
The cabling list number and cabling plan sections in the allocation tables
below refer to chapter
Cable
(T26139-)
SATA cable
Y3958-V205
Slimline ODD SATA
power cable
Y3986-V302
Ê Connect the SATA and power cables as shown in the tables above.
746
"Removing accessible drive filler covers" on page
"Removing accessible drive covers" on page
"Cabling" on page
Cabling
from
list no.
20
Slimline ODD
Slimline ODD
8A / 8B
(15-pin SATA)
Upgrade and Maintenance Manual
334.
309.
909.
to
System board
connector SATA 1
3.5-inch HDD
backplane 2
connector X9
(4-pin connector)
TX300 S7 / RX350 S7
656.
657.
Cabling
plan
16.2.1
16.2.7
16.2.4