Removing 2.5-Inch Hdd / Ssd Modules; Required Tools; Preliminary Steps - Fujitsu PRIMERGY TX300 S7 Upgrade And Maintenance Manual

Table of Contents

Advertisement

7.2.6

Removing 2.5-inch HDD / SSD modules

Customer Replaceable Units (CRU)
Average task duration: 5 minutes
7.2.6.1

Required tools

Preliminary and concluding steps: tool-less
Removing a 2.5-inch HDD / SSD module: tool-less
7.2.6.2

Preliminary steps

Before removing a 2.5-inch HDD / SSD module, perform the following steps:
Ê If the HDD / SSD module to be removed is combined into a RAID array,
please proceed as follows:
RAID level
RAID 0
RAID 1
RAID 5
TX300 S7 / RX350 S7
Procedure
Only remove an HDD module combined in a RAID 0
array if defective.
V
CAUTION!
Removing an operational HDD module will
result in data loss!
Removing an HDD module from a RAID 1 or RAID 5
array will not result in data loss.
However, the removed drive needs to be replaced
immediately by an HDD module of the same or larger
capacity.
I
After replacing the HDD module, RAID rebuild
will be performed as a background process as
described in section
rebuild" on page
Upgrade and Maintenance Manual
Hard disk drives / solid state drives
"Performing a RAID array
166.
219

Advertisement

Table of Contents
loading

This manual is also suitable for:

Primergy rx350 s7

Table of Contents