4.13
Switching on the server
V
CAUTION!
Before switching on the server, make sure the top / side cover is
●
closed. In order to comply with applicable EMC regulations
(regulations on electromagnetic compatibility) and satisfy cooling
requirements, the PRIMERGY TX300 S7 / RX350 S7 server must
not run while the top / side cover is removed.
Follow the safety instructions in chapter
●
page
51.
Ê Connect all peripheral cables to the rear connector panel of the server.
Ê Connect and secure the power cords as described in section
the server to the mains" on page
Ê Connect all power cords to the power outlets.
I
To provide true phase redundancy, the second power supply should
be connected to a different AC power source from the other supply. If
one AC power source should fail, the server will still continue to run.
Figure 73: On / Off button on the front panel
Ê Press the On / Off button to start up the server.
Ê Ensure that the power-on indicator above the On / Off button is lit green.
I
For more information, refer to section
indicators" on page
TX300 S7 / RX350 S7
133.
958.
Upgrade and Maintenance Manual
Basic hardware procedures
"Important information" on
"Connecting
"Front panel controls and
139