7.2.7
Replacing a 2.5-inch HDD / SSD module
Customer Replaceable Units (CRU)
Average task duration: 5 minutes
V
CAUTION!
Only remove an HDD / SSD module during operation if the drive is
●
not currently being accessed. Observe the indicators on the
HDD / SSD module, as described in the "PRIMERGY
TX300 S7 / RX350 S7 Server" operating manual".
Under no circumstances should you remove an HDD / SSD module
●
while the system is in operation if you are not sure that the drive is
operated by a RAID controller and belongs to a disk array that is
operating in RAID level 0, 1, 1E, 10, 5, 50, 6 or 60.
An HDD / SSD module can only be replaced during operation in
conjunction with a corresponding RAID configuration.
All HDD / SSD modules (drives) must be uniquely identified so that
●
they can be reinstalled in their original mounting locations later. If this
is not done, existing data can be lost.
7.2.7.1
Required tools
Preliminary and concluding steps: tool-less
●
Replacing a 2.5-inch HDD / SSD module: tool-less
●
TX300 S7 / RX350 S7
Upgrade and Maintenance Manual
Hard disk drives / solid state drives
223