Fujitsu PRIMERGY TX300 S7 Upgrade And Maintenance Manual page 151

Table of Contents

Advertisement

iRMC recovery procedure
I
For the Japanese market, follow the instructions provided separately.
Ê Prepare a USB stick including the bootable iRMC firmware update image.
Ê Ensure that the server has been shut down and disconnected from the
mains as described in section
Ê Connect the USB stick to the USB port.
I
Ensure that only the USB device with the iRMC firmware is connected
to the USB port. Remove all other USB devices temporarily.
Ê Connect the server to the mains while pushing the ID button on the front
panel. Ask a second person to help you if necessary.
Ê Ensure that the Global Error indicator and the ID indicator are flashing to
indicate that the server is entering the iRMC recovery state.
Ê Press the Power On / Off button. The system starts the POST process.
I
In iRMC recovery mode, the "FUJITSU" logo does not show up.
Ê The system will detect the USB stick.
I
If the BIOS cannot identify the USB stick, the pop-up message
Failed to boot for Emergency flash. Please Reset now.
will show up in the center of the screen.
Ê Choose the Recovery_L option from the update tool menu to start the iRMC
update process.
V
CAUTION!
Do not interrupt the iRMC upgrade process after it has started. If the
process is interrupted, the iRMC BIOS may be permanently
corrupted.
I
If the iRMC does not work after flashing, disconnect the system from
the mains and reconnect it again.
Ê Shut down the server by pressing the power On / Off button.
Ê Disconnect the server from the mains to exit the iRMC recovery state.
TX300 S7 / RX350 S7
"Shutting down the server" on page
Upgrade and Maintenance Manual
Basic software procedures
71.
151

Advertisement

Table of Contents
loading

This manual is also suitable for:

Primergy rx350 s7

Table of Contents