Always connect the server and the attached peripherals to the same power
●
circuit. Otherwise you run the risk of losing data if, for example, the server is
still running but a peripheral device (e.g. memory subsystem) fails during a
power outage.
Data cables must be adequately shielded.
●
Ethernet cabling has to comply with EN 50173 and EN 50174-1/2 standards
●
or ISO/IEC 11801 standard respectively. The minimum requirement is a
Category 5 shielded cable for 10/100 Ethernet, or a Category 5e cable for
Gigabit Ethernet.
Route the cables in such a way that they do not create a potential hazard
●
(make sure no-one can trip over them) and that they cannot be damaged.
When connecting the server, refer to the relevant instructions in this manual.
Never connect or disconnect data transmission lines during a storm (risk of
●
lightning hazard).
Make sure that no objects (e.g. jewelry, paperclips etc.) or liquids can get
●
inside the server (risk of electric shock, short circuit).
In emergencies (e.g. damaged casing, controls or cables, penetration of
●
liquids or foreign bodies), contact the system administrator or your customer
service team. Only disconnect the system from the mains power supply if
there is no risk of harming yourself.
Proper operation of the system (in accordance with IEC 60950-1 resp.
●
EN 60950-1) is only ensured if the casing is completely assembled and the
rear covers for the installation slots have been fitted (electric shock, cooling,
fire protection, interference suppression).
Only install system expansions that satisfy the requirements and rules
●
governing safety and electromagnetic compatibility and those relating to
telecommunication terminals. If you install other expansions, they may
damage the system or violate the safety regulations. Information on which
system expansions are approved for installation can be obtained from our
customer service center or your sales outlet.
The components marked with a warning notice (e.g. lightning symbol) may
●
only be opened, removed or exchanged by authorized, qualified personnel.
Exception: CSS components can be replaced.
The warranty is void if the server is damaged during installation or
●
replacement of system expansions.
TX300 S7 / RX350 S7
Upgrade and Maintenance Manual
Important information
53