Ê When working on a rack-mounted server, secure it in the rack as described
in section
"Sliding the server into the rack" on page
If the server has been completely removed from the rack for maintenance
purposes, reinstall and secure it in the rack as described in section
"Mounting the server in the rack" on page
Ê Reconnect the AC power cords to the power supply units and secure them
with PSU cable brackets as described in section
the mains" on page
Ê If applicable, update the firmware of the RAID controller that has been
connected to the BBU as described in section
firmware" on page
Ê Enable boot watchdog functionality as described in section
boot watchdog functionality" on page
Note on BBU charging and calibration
The BBU may be deeply discharged due to extended storage time and wrongly
show as bad or defective in the ServerView RAID Manager.
In this case, the BBU will automatically enter a trickle charge cycle for recovery.
This initial charge may take up to 8 hours before the BBU will initiate a
recalibration cycle.
Ê Enter the ServerView RAID Manager and check the current BBU status.
I
For further information, please refer to the "ServerView Suite RAID
Management" user guide, available online at
http://manuals.ts.fujitsu.com (http://jp.fujitsu.com/platform/server/
primergy/manual/
Suite DVD 2 supplied with your PRIMERGY server.
Ê If the BBU is shown as bad or defective, do not power off the server for at
least 8 hours to allow the charge and calibration cycles to finish.
Ê If the BBU status does not change after 8 hours, please try to initiate the
recalibration process manually using the ServerView RAID Manager.
I
If this procedure still does not fix the BBU status, please contact your
local Fujitsu customer service partner.
TX300 S7 / RX350 S7
133.
153.
for the Japanese market) or from the ServerView
Upgrade and Maintenance Manual
Expansion cards and backup units
132.
130.
"Connecting the server to
"Updating RAID controller
159.
"Enabling SVOM
549