13.2.1.11 Using the front management LAN connector

In order to use the front management LAN connector to access the iRMC S3
management controller, please proceed as follows:
Ê Ensure that Management LAN has been enabled in the BIOS:
Ê Enter the BIOS.
Ê Select the Server Mgmt menu.
Ê Under iRMC LAN Parameters Configuration, make sure that the
Management LAN setting is set to Enabled.
Ê Save your changes and exit the BIOS.
I
The front management LAN connector can be used to access the
iRMC S3 with either of the Management LAN Port settings enabled,
Management or Shared.
For detailed information on how to access the BIOS and modify
settings, refer to the "D2949 BIOS Setup Utility for PRIMERGY
TX300 S7 / RX350 S7" reference manual.
Ê Connect a client computer (e.g. notebook) to the front management LAN
connector.
I
It is not possible to simultaneously access the iRMC S3 from the front
and rear management LAN connectors. As soon as a LAN cable is
connected to the front management LAN connector, the iRMC S3
cannot be accessed via the rear management LAN connector.
After removing the LAN cable from the front management LAN
connector, the iRMC S3 will immediately become accessible via the
rear management LAN connector again.
Ê Accessing the iRMC S3 using the front management LAN connector is only
possible via the preset IP address 192.168.1.1 and cannot be configured
otherwise.
Configure your client computer to use any static IP address on subnet
192.168.1.x (except 192.168.1.1) with subnet mask 255.255.255.0.