9.5.1.4
Connecting GPGPU / coprocessor card power cables to the
power backplane
Ê If applicable, connect the GPGPU card power cables to the power
backplane as described in section
to the power backplane" on page
9.5.1.5

Removing PCI slot brackets

Figure 313: Removing the PCI slot bracket (A)
I
Ensure that the GPGPU / coprocessor card power cables have been
connected to the power backplane as described in section
GPGPU card power cables to the power backplane" on page
Ê Press out on the locking latch to disengage the PCI slot bracket locking bar
(1, see close-up).
Ê Fold up (2) and remove (3) the PCI slot bracket locking bar.
I
The PCI slot mounting bar is no longer required if installing one or two
GPGPU / coprozessor cards. Set aside and save the mounting bar for
future use.