Fujitsu PRIMERGY TX300 S7 Upgrade And Maintenance Manual page 69

Table of Contents

Advertisement

No. Description
1
Indicate CSS button
Using the Indicate CSS button
Ê Shut down and power off the server.
Ê Disconnect the AC power cord from the system.
I
It is mandatory to disconnect power cords in order to use the Indicate
CSS functionality.
Ê Remove the air duct as described in section
on page
100.
Ê Press the Indicate CSS button (1) to highlight defective components.
Component LEDs
I
LEDs A, B and C are visible from the outside on the server rear. All other
LEDs are only visible if the server cover has been opened.
Indicator
A
ID indicator
CSS
B
(Customer Self
Service)
GEL
C
(Global Error
LED)
TX300 S7 / RX350 S7
Status
Description
server has been highlighted using
ServerView Operations Manager or the
blue on
ID button on the front panel for easy
identification
off
no critical event (CSS component)
yellow on
prefailure detected (CSS component)
yellow
CSS component failure
flashing
off
no critical event (non CSS component)
prefailure detected (non CSS
orange on
component)
non CSS component failure
Possible reasons:
orange
– sensors report overheating
flashing
– sensor is defective
– CPU error
– software reports an error
Upgrade and Maintenance Manual
Basic hardware procedures
"Removing the system air duct"
69