Hobart 9OC24S Operation Manual page 109

Self-propelled generator set
Table of Contents

Advertisement

GENERATOR
DIVISION
HOBART
BROTHERS
COMPANY
OPERATION,
MAINTENANCE,
AND
OVERHAUL
MANUAL,
TM-240A
SELF-PROPELLED
GENERATOR
SET, SPEC.
NO.
5381A
the end of each 200 hours of operation,
or every
three
months if the equipment
is operated
less than 300 hours in the three
months period.
"AR" services
are
performed
on an "AS REQUIRED"
basis.
3.
Inspection/Check
A.
General
Inspections,
checks,
and maintenance
are described
in general
here.
More
specific
and detailed
information
contained
in 2-2
and 2-3,
will
be referenced
when applicable.
B.
"AR" Checks
and Operations
(As Required)
(1)
Engine
(a)
Change
air cleaner
cartridge
A definite
time schedule
for changing
the air cleaner
cartridge
cannot
be established.
Observe
the indicator
when the engine
is stopped.
When
the flag
is locked
in full view,
change
the cartridge.
See 2-2,
Para.
3.
(b)
Check
engine
"blow-by"
as required
if the engine
lacks power or uses
oil excessively.
Refer to the Cummins
Operation
and
Maintenance
Manual.
(c)
Tighten
manifold,
muffler,
and exhaust
pipe attaching
hardware
(nuts
and capscrews)
as required.
(d)
Tighten
all attaching
hardware
as required.
(2)
Electrical
system (12-V
DC)
(a)
Check
battery
terminals
Anytime
the battery
compartment
doors (Ref.
2-2,
Fig.
15) are opened
for any reason,
visually
check
battery
cable
connectors
and battery
posts.
If corrosion
is observed,
disconnect
cables
and clean
battery
posts and connectors
with a wire
brush or special
battery
post-and-
connector
cleaning
tool.
Coat posts and connectors
with a light
film
of petroleum
lubricant
before reconnecting
cables.
(3)
Drive
train
(a)
Clutch
pedal
travel
Ott
30/73
2-l

Advertisement