Engine Specifications - Hobart 9OC24S Operation Manual

Self-propelled generator set
Table of Contents

Advertisement

~OEIAR~
I
t
"c
QD
;MOTOR
GENERATOR
DIVISION
z
2
HOBART
BROTHERS
COMPANY
b.
LI,,\@+
OPERATION,
MA!NTENANCE,
AND
OVERHAUL
MANUAL,
TM-240A
SELF-PROPELLED
GENERATOR
SET,
SPEC.
NO.
5381A
(4)
Engine
idle speed adjustment
Engine
idle speed is set at the factory.
The adjustment
is then sealed to dis-
courage tampering.
Idle speed should not be changed by the user.
If adjustment
is required,
contact
the local Cummins
Distributor.
The recommended
idle speed
is 650 RPM,
plus or minus 25 RPM.
NOTE:
A stroboscope
is required
for engine
idle speed checks.
Type engine
Mode I
Cummins specification
no.
Engine
governed
speed
Idle speed
Speed limiting
governor
Firing
order
Fuel pump
Fuel pump speed limiting
governor
Lubricating
oil pressure at 2400 RPM
Engine
coolant
temperature
V-8
diesel
modified
V-504-C2
10
1826-01
2400 RPM
625 to 675 RPM
approximately
2640 RPM
1-5-4-8-6-3-7-2
Type PTG
Automotive
type
45 to 75 PSI
165 to 195 deg F.
(73.9
to 90.6
deg C.)
Engine
Specifications
Figure
8
(5)
Engine
speed limiting
adjustment
The speed limiting
adjustment
is also set and sealed at the factory.
Speed should
be limited
to approximately
2640
RPM.
If adjustment
is required,
contact your
local Cummins Distributor.
D.
Engine
Accessories
Adjustment
(1)
Generator
and fan belt adjustment
Refer
to 2-2,
Para.
8, D and E,for
belt adjustment
instructions.
NOTE:
Replace
fan belts with a matched set if replacement
is necessary.
E.
Electric-Hydraulic
Governor
System Adjustment
All
of the electric-hydraulic
governor
system main components,
namely the magnetic
pickup,
hydraulic
actuator,
and electric
control
box,
have critical
adjustments
which
can affect
engine
performance
and therefore,
generator
output.
Actuator-to-fuel
ccntrol
lever adjustment
can also affect
engine
performance.
2-3