Fujitsu Eternus DX100 S3 User Manual page 48

Fujitsu eternus cli user's guide
Hide thumbs Also See for Eternus DX100 S3:
Table of Contents

Advertisement

Chapter 2 Status Display
2.1 Storage System Status > show fru-ce
CA Slot#
DMA Port# DMA Port status and the status code
BIOS#
CM EXP
CM EXP# InPort#
SAS Cable# (OUT)
CM RTC
CM NVRAM
CM FPGA
CM LAN Port#
DI# Port#
SATA SSD Controller
SATA SSD Controller Active EC
SATA SSD Controller Next EC
SATA SSD Controller Firmware Version
SCU
SCU Voltage
PCH
CA Slot status and the status code
BIOS status and the status code
CM EXP status and the status code
CM EXP InPort status and the status code
SAS Cable (OUT) status and the status code
CM RTC status and the status code
CM NVRAM status and the status code
CM FPGA status and the status code
CM LAN Port status and the status code
DI port status and the status code
Boot and Utility Device (BUD) controller status and the status code
(ETERNUS DX100 S3/DX200 S3 and ETERNUS DX200F only)
Edition Control (EC) number that is currently operating in the relevant BUD controller
(ETERNUS DX100 S3/DX200 S3 and ETERNUS DX200F only)
EC number that will start up next in the relevant BUD controller
(ETERNUS DX100 S3/DX200 S3 and ETERNUS DX200F only)
BUD controller firmware version
(ETERNUS DX100 S3/DX200 S3 and ETERNUS DX200F only)
SCU (System Capacitor Unit) status and the status code (ETERNUS DX100 S3/DX200 S3
and ETERNUS DX200F only)
SCUs are electric double layer capacitors embedded in a controller module. SCUs provide
the power to move the cache data to the SATA SSD flash memory if there is a power
outage.
Charging voltage of SCU (ETERNUS DX100 S3/DX200 S3 and ETERNUS DX200F only)
PCH status and the status code
48
ETERNUS CLI User's Guide
Copyright 2014 FUJITSU LIMITED
P2X0-1210-05ENZ0

Hide quick links:

Advertisement

Table of Contents
loading