ebs - Specify the "Excess Burst Size". The unit is Kbytes.
●
<value> - Enter the excess burst size value here.
●
color_blind - (Optional) Specify the meter mode to be color-blind. The default is color-blind mode.
●
color_aware - (Optional) Specify the meter mode to be color-aware. When this code is specified, user
●
could set the "in-coming packet color" by using command "config color_aware". The final color of
packet is determined by the initial color of packet and the metering result.
conform - (Optional) Specify the action when packet is in "green color".
●
permit - (Optional) Permit the packet.
●
replace_dscp - Changes the DSCP of the packet.
●
-
<value 0-63> - Enter the replace DSCP value here. This value must be between 0 and 63.
counter - (Optional) Specifies the ACL counter. This is optional. The default is "disable". The
●
resource may be limited so that a counter cannot be turned on. Counters will be cleared when the
function is disabled.
enable - Specifies that the ACL counter parameter will be enabled.
●
disable - Specifies that the ACL counter parameter will be disabled.
●
exceed - Specify the action when packet is in "yellow color".
●
permit - Permit the packet.
●
replace_dscp - (Optional) Changes the DSCP of the packet.
●
-
<value 0-63> - Enter the DSCP replace value here. This value must be between 0 and 63.
drop - Drops the packet.
●
counter - (Optional) Specifies the ACL counter. This is optional. The default is "disable". The
●
resource may be limited so that a counter cannot be turned on. Counters will be cleared when the
function is disabled.
enable - Specifies that the ACL counter parameter will be enabled.
●
disable - Specifies that the ACL counter parameter will be disabled.
●
violate - Specify the action when packet is in "red color".
●
permit - Permit the packet.
●
replace_dscp - (Optional) Changes the DSCP of the packet.
●
-
<value 0-63> - Enter the DSCP replace value here. This value must be between 0 and 63.
drop - Drops the packet.
●
counter - (Optional) Specifies the ACL counter. This is optional. The default is "disable". The
●
resource may be limited so that a counter cannot be turned on. Counters will be cleared when the
function is disabled.
enable - Specifies that the ACL counter parameter will be enabled.
●
disable - Specifies that the ACL counter parameter will be disabled.
●
delete - Delete the specified "flow_meter".
●
Restrictions
Only Administrator, Operator and Power-User level users can issue this command.
Extreme Networks EAS 200-24p Switch CLI Manual