Automatic Route Selection
NOTE:
Pool routes must be programmed before you assign Facility Restriction
Levels.
Facility Restriction Levels are assigned to Tables 1 through 18. Tables 17 and
18, the Default Toll and Default Local tables respectively, cannot be changed.
Summary: Facility Restriction Level
Programmable by
Mode
Idle Condition
Planning Form
Factory Setting
Valid Entries
Inspect
Copy Option
Console Procedure
PC Procedure
Procedure: Facility Restriction Level
Console Display/Instructions
1
Select the Tables menu.
System Programming:
Make a selection
System
Extensions
SysRenumber
SysRenumber
Operator
Tables
LinesTrunks
AuxEquip
Exit
NightSrvce
2
Select Automatic Route Selection.
Tables:
Make a selection
AllowList
ARS
A11owTo
Disallow
DisallowTo
Exit
System manager
Hybrid/PBX
Not required
Form 3f, Automatic Route Selection Tables
Form 3g, Automatic Route Selection Default and Special
Numbers Tables
3
0 t 0 6
No
No
Tables → ARS → Sub A FRL or More and Sub B FRL → Dial
table no, and pool route no. → Enter → Dial restriction level
→ Enter → Exit → Exit
[ F8 ] → [ F6 ] → [ F4 ] or [ PgUp ] and [ F1 ] → Type table no. and pool
route no. → [ F10 ] → Type restriction level → [ F10 ] → [ F5 ] → [ F5 ]
Additional Information
>