Lines and Trunks
The setting selected applies to all trunks in the system because trunks cannot
be programmed individually. The reliable/unreliable setting does not apply to
loop-start trunks emulated on a T1 facility. If you specify a reliable disconnect
for trunks programmed with a short hold disconnect interval (see "Hold
Disconnect Interval"), active calls as well as trunks on hold may be
disconnected. For more information about reliable and unreliable disconnect
and its implications, see the Feature Reference.
NOTE:
Certain features (Remote Call Forwarding and Transfer to outside numbers) and
applications (CMS, AUDIX Voice Power, and MERLIN MAIL) are not
recommended with loop-start trunks. See "Hold Disconnect Interval. "
Summary: Disconnect Signaling Reliability
Programmable by
Mode
Idle Condition
Planning Form
Factory Setting
Valid Entries
Inspect
Copy Option
Console Procedure
PC Procedure
Procedure: Disconnect Signaling Reliability
Console Display/Instructions
1
Select the Lines and Trunks menu.
System Programming:
Make a Selection
System
Extensions
SysRenumber
Options
Operator
Tables
LinesTrunks AuxEquip
NightSrvce
Exit
4-32
Programming Procedures
System manager, Integrated Administration
All
Not required
Form 2c, System Numbering: Line/Trunk Jacks
Unreliable
Unreliable, Reliable
No
No
LinesTrunks → TT/LS Disc → LS Disconnect → Yes or No →
Enter → Exit → Exit
[ F4 ] → [ F3 ] → [ F1 ] or [ F2 ] → [ F10 ] → [ F5 ] → [ F5 ]
Additional Information
PC
[ F4 ]