Lines and Trunks
Console Display/Instructions
2
Specify whether or not a toll prefix is needed.
Return to the System Programming menu.
3
Select Exit three times.
Hold Disconnect Interval
Use this procedure to specify the number of milliseconds before a loop-start
line/trunk is released when a caller on hold hangs up and abandons the call.
This can be specified as either a long interval (450 ms) or a short interval (50
ins). The hold disconnect interval applies to loop-start trunks connected to 400,
408, or 800 modules; it does not apply to emulated loop-start trurlks (T1 facility).
NOTES
1. If the disconnect interval is longer than the telephone company setting, the
line is not released when a caller on hold hangs up.
2. Do not program a short interval unless the local telephone company's central
office is the crossbar type.
3. Do not program a reliable disconnect for lines/trunks with a short hold
disconnect interval. This can cause active calls as well as the lines/trunks on
hold to be disconnected. See "Disconnect Signaling Reliability. "
For more information on Hold Interval Disconnect and Reliable and Unreliable
Disconnect, see the Feature Reference.
Summary: Hold Disconnect
Programmable by
Mode
Idle Condition
Planning Form
Factory Setting
Valid Entries
Inspect
Copy Option
4-36
Programming Procedures
Additional Information
Toggle the green LED on or
off as required.
On = toll prefix needed.
Off = toll prefix not needed.
Interval
System manager
All
Not required
Form 2c, System Numbering: Line/Trunk Jacks
Long interval (450 ms)
Long interval, Short interva
No
No
PC
[ F5 ] [ F5 ] [ F5 ]