Lines and Trunks
Procedure: Type of Trunk
Console Display/Instructions
1
Select the Lines and Trunks menu.
System Programming: >
Make a selection
Extensions
System
Options
SysRenumber
Operator
Tables
LinesTrunks AuxEquip
NightSrvce
Exit
2
Select Loop-Start/Ground-Start/DSl.
Lines and Trunks:
Make a selection
PRI
LS/GS/DSl
TIE Lines
copy
RemoteAccss
TT/LS Disc
DID
Pools
Tool Type
Exit
3
Enter the slot number in the control unit that contains the module
( nn = 1 to 17).
Loop/Ground/DS1:
Enter slot number (1-17)
Backspace
Exit
Enter
4
Save your entry.
Select Enter.
5
Specify the type of trunks connected to the module.
**** GS/LS Slot xx:
Select one
All Ground
GroundStart
Loop Start
All Loop
Exit
4–26
Programming Procedures
Additional Information
>
Module is: 400,408, 408GS/LS-MLX,
800GS/LS, or 800 GS/LS-lD.
Dial or type [ nn ].
**** = 400, 408, 408-MLX, or 800 modules
xx = slot number entered in Step 3
Select GroundStart or
Loop Start and go to Step 6.
Or, select All Ground or
All Loop and go to Step 9.
PC
[ F4 ]
[ F1 ]
[ F10 ]
[ F1 ]
[ F2 ]
[ F6 ]
[ F7 ]

Advertisement