Performing Internal Logging; Internal Logging By Sysmac Studio - Omron ZW-8000 Series User Manual

Confocal fiber type displacement sensor
Table of Contents

Advertisement

3-8 Performing internal logging

Up to 2000000 data of measurement values can be logged in the Sensor Controller's internal memory.
Internal logging can be started or ended using Sysmac Studio, parallel I/O, or non-procedural communications
commands.
The operating procedures for each method are shown below.
Function
Specify start timing
Specify end timing
Terminate logging
Output logging data
Clear logging data
Get logging information
The settings that can be enabled for each method are shown below.
Function
Overwrite mode
Sets the operation to be performed when the logging
count exceeds the set number of logging data.
Label insert mode
Sets the operation to be performed when logging input
is turned on.
Output data format
Important
Internal logging cannot be executed when in the following settings.
• When overwrite mode is ON or when the measurement cycle (internal synchronous measurement mode) is less
than 40µs

Internal logging by Sysmac Studio

Data logging conditions and logging start/end timing can be set with Sysmac Studio.
 Multi view Explore
→ Edit pane
→ Online setting window : [Internal Logging]
114

Performing internal logging

Sysmac Studio
Press the "Logging Start" button.
Stops automatically after the specified
number of logging data has been saved.
After pressing the "Logging Start" button,
press the displayed "Terminate" button
Press the "Save to file (Sensor → PC)"
button.
• Automatically cleared after the "Logging
Start" button is pressed if clear logging
data is turned ON when logging starts
• Cleared when "Clear Logging Data" button
is pressed
Press the "Get logging information" button.
OFF: Internal logging is stopped.
ON : The oldest logging data is overwritten.
OFF: No operation.
ON : When logging input is turned on, inserts label
into logging data.
: [(ZW model name)] (double click)
: [Online] icon (
Parallel I/O
LOGGING input ON
LOGGING input OFF
LOGGING input OFF
Send LO/LG
command
Send LC command
-
Sysmac Studio
OFF
OFF
ASCII
)
Non-procedural commu-
nications commands
Send LS command
Send LE command
LE command
Send LO/LG command
Send LC command
Send LI command
Parallel I/O
Non-procedural
communications
commands
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ASCII/Binary
ASCII/Binary
ZW-8000/7000/5000
User's Manual