Monitoring
3-2-8

Monitor Test (TEST)

start address/
end address/
data setting
When an
error occurs
This operation repeatedly executes (at 1-second intervals) either the Read,
Write, Auto Read, or Auto Write command in specified addresses of the Data
Carrier. Any command errors that occur are displayed. Use this operation to
test and adjust the distance of the Data Carrier from the Read/Write Head (or
Antenna), and the travel speed of the Data Carrier. Refer to the following fig-
ure.
Before performing this operation, select the address and the data you want to
read or write. Refer to 3-2-4 Address/Data Setting for details.
HEAD 1 PAGE 1
STadrs1F data 29
ST: start address
ED: end address
start address
TEST 1 2 3 4
TEST
RD WT AR AW
These commands are
selected by pressing the
following keys:
1
: read (RD)
2
: write (WT)
3
: auto read (AR)
4
: auto write (AW)
TEST RD
1
TEST RD
error72 NO DC E
Error code
number
HEAD 1 PAGE 1
RESET
STadrs1F data 29
Data to
be written
end address
Error
message
First, select the address to
be accessed and the data
to be written or read. When
executing Write or Auto
Write, remember to set the
data to be written as well
as the address.
Press the TEST key. Exe-
cute a command from the
command menu (dis-
played on the screen) by
pressing the number that
corresponds to the com-
mand you want to execute.
In this example, the READ
command is selected.
From the start address to
the end address of the Data
Carrier, the READ com-
mand is executed on a step-
by-step basis. In one-se-
cond intervals, data is read
and checked for errors. If an
error occurs while a com-
mand is being executed, the
corresponding error number
and message are displayed.
3-2-10 Error Codes
(Refer to
The error message
and code disappear auto-
matically if the next com-
mand is executed correctly.
While the TEST operation
is being performed, the T/R
LED indicator on the ID
Sensor Unit blinks.
To begin another command
or to abort the TEST opera-
tion, press the RESET key
and the display will return
to the reset status.