probe-suppression
Use the
probe-suppression
can also optionally set the RSS threshold and enable or disable force disassociate. The
command is accessible from ap:defaults:ap37xx, ap:defaults:ap38xx, ap:defaults:ap3801,
suppression
and ap:<serial> radio contexts for ap37xx and ap38xx APs.
probe-supression disable | enable
Parameters
disable | enable
Usage
Probe requests from unassociated clients are not responded to if RSS is less than the RSS-threshold.
Associate requests from clients that are not associated are not responded to if RSS is less than the RSS-
threshold. Probe requests from clients that are associated are not responded to if the client's averaged
RSS (after including the Probe Request) is less than the RSS-threshold.
If force-disassociate is enabled, associated clients are sent Disassociate, if the averaged RSS is less than
RSS-threshold minus 5dBm.
Example
The following example enables probe suppression on radio 1 of AP 1111111111113705:
WLC.siemens.com
ptype
Use the
command to select the Protection Type. The
ptype
radio2 contexts (except ap37xx) of the CLI.
ptype ( cts only | rts cts )
Parameters
cts only
rts cts
Example
The following example sets the protection type to CTS:
WLC.siemens.com
SCALANCE WLC711 CLI Reference Guide
command to enable or disable probe suppression on an AP radio. You
Enables or disables probe suppression for this radio context.
:ap:1111111111113705:radio1# probe-suppression enable
Specifies the Clear to Send (CTS) type.
Specifies the Request to Send (RTS) and Clear to Send (CTS) types
:ap:defaults:11n:radio2# ptype cts only
probe-suppression
command is accessible from all ap:
ptype