Siemens scalance WLC711 Reference Manual page 116

Hide thumbs Also See for scalance WLC711:
Table of Contents

Advertisement

Parameters
hours
Usage
The
secure-tunnel
be run. The default is 0 hours, indicating the tunnel remains enabled until it is manually disabled. Valid
entries are 0, or any number between 24-3600. When this value expires, the tunnel becomes disabled.
Use the
secure-tunnel disable
Example
The following example enables a secure tunnel for 24 hours:
WLC.siemens.com
show
Use the
command to display AP information. The
show
ap:<serial> and ap:defaults:11n, ap37xx, ap38xx, ap3801, and professional-antenna contexts of the CLI.
show
Parameters
None
Examples
The following example displays 802.11n AP information:
WLC.siemens.com
ssh enabled
poll_timeout 22
client_session
no persistent
no bcast_disassoc
country United States
no lldp
led-mode normal
lbs-status enabled
secure-tunnel data
secure-tunnel-lifetime 24
ipmcast-assembly disabled
The following example displays ap37xx information:
WLC.siemens.com
ssh enabled
poll_timeout 22
client_session
persistent
SCALANCE WLC711 CLI Reference Guide
Specifies the number of hours the tunnel will remain enabled.
command must be enabled before the
command to terminate a tunnel.
:ap:defaults:ap37xx# secure-tunnel-lifetime 24
:ap:defaults:11n# show
:ap:defaults:ap37xx# show
secure-tunnel-lifetime
command is accessible from the
show
ap Commands
show
command can
116

Advertisement

Table of Contents
loading

Table of Contents