Connecting
7.2 Interfaces for the controller
Figure 7-29
To prevent unwanted interaction, the failsafe digital input must not perform its own self-test
with dark pulses.
7.2.11

Connecting the motor holding brake

Overview
The converter controls the motor holding brake via a digital output.
Requirement
The current or voltage rating of the digital output is suitable for connecting the motor holding
brake or a coupling relay.
Description
If the current or voltage rating of the digital output is not sufficient, you must control the motor
holding brake via a coupling relay on the digital output.
The digital output that the converter is to use to control the motor holding brake must be
interconnected with the brake control signal:
• Digital output DO 0: c0730 = r0899.12
• Digital output DO 1: c0731 = r0899.12
• Digital output DO 2: c0732 = r0899.12
190
Connection of a failsafe digital input
Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB