A06901
Braking Module: Pre-alarm I2t shutdown
Message value:
%1
Message class:
Braking Module faulted (14)
Drive object:
B_INF
Reaction:
NONE
Acknowledge:
NONE
Cause:
The Braking Module "Booksize" format signals "Pre-alarm I2t shutdown" via terminal X21.3.
This signal is wired to a system digital input and correspondingly interconnected using binector input p3865[0...7].
Note:
This function is not supported for the "chassis" format.
Remedy:
- reduce the number of braking operations.
- check binector input p3865[0...7] and the wiring from terminal X21.3 of the particular Braking Module.
A06904 (N)
Braking Module internal is inhibited
Message value:
%1
Message class:
Braking Module faulted (14)
Drive object:
B_INF
Reaction:
NONE
Acknowledge:
NONE
Cause:
The internal Braking Module was inhibited via binector input p3680 = 1 signal.
In the inhibited state, energy cannot be dissipated using the braking resistor.
See also: p3680 (Braking Module internal inhibit)
Remedy:
Release the internal Braking Module (BI: p3680 = 0 signal).
Reaction upon N:
NONE
Acknowl. upon N:
NONE
A06905
Braking Module internal I2t shutdown alarm
Message value:
%1
Message class:
Braking Module faulted (14)
Drive object:
B_INF
Reaction:
NONE
Acknowledge:
NONE
Cause:
The internal Braking Module outputs an alarm due to the high I2t value.
80% of the maximum switch-on duration of the braking resistor has been reached.
Note:
This message is also displayed via BO: p3685.
See also: r3685 (Digital Braking Module: Pre-alarm I2t shutdown)
Remedy:
Reduce the number of braking operations.
F06906 (A)
Braking Module internal fault
Message value:
%1
Message class:
Braking Module faulted (14)
Drive object:
B_INF
Reaction:
NONE
Acknowledge:
IMMEDIATELY
Cause:
The internal Braking Module outputs a fault due to overcurrent or an excessively high I2t value and is therefore
inhibited.
Note:
This message is also displayed via BO: p3686.
Fault value (r0949, interpret bitwise binary):
Bit 0 = 1: I2t exceeded
Bit 1 = 1: overcurrent
See also: r3686 (Digital Braking Module Fault)
Remedy:
Reduce the number of braking operations.