4 Faults and alarms
4.2 List of faults and alarms
Remedy:
- check the connection between the motor and load.
- adapt the parameterization corresponding to the load.
A07921
Drive: Torque/speed too high
Message value:
-
Message class:
Application / technological function faulted (17)
Drive object:
VECTOR_G
Reaction:
NONE
Acknowledge:
NONE
Cause:
The torque deviates from the torque/speed envelope characteristic (too high).
Remedy:
- check the connection between the motor and load.
- adapt the parameterization corresponding to the load.
A07922
Drive: Torque/speed out of tolerance
Message value:
-
Message class:
Application / technological function faulted (17)
Drive object:
VECTOR_G
Reaction:
NONE
Acknowledge:
NONE
Cause:
The torque deviates from the torque/speed envelope characteristic.
Remedy:
- check the connection between the motor and load.
- adapt the parameterization corresponding to the load.
F07923
Drive: Torque/speed too low
Message value:
-
Message class:
Application / technological function faulted (17)
Drive object:
VECTOR_G
Reaction:
OFF1 (NONE, OFF2, OFF3)
Acknowledge:
IMMEDIATELY
Cause:
The torque deviates from the torque/speed envelope characteristic (too low).
Remedy:
- check the connection between the motor and load.
- adapt the parameterization corresponding to the load.
F07924
Drive: Torque/speed too high
Message value:
-
Message class:
Application / technological function faulted (17)
Drive object:
VECTOR_G
Reaction:
OFF1 (NONE, OFF2, OFF3)
Acknowledge:
IMMEDIATELY
Cause:
The torque deviates from the torque/speed envelope characteristic (too high).
Remedy:
- check the connection between the motor and load.
- adapt the parameterization corresponding to the load.
F07925
Drive: Torque/speed out of tolerance
Message value:
-
Message class:
Application / technological function faulted (17)
Drive object:
VECTOR_G
Reaction:
OFF1 (NONE, OFF2, OFF3)
Acknowledge:
IMMEDIATELY
Cause:
The torque deviates from the torque/speed envelope characteristic.
Remedy:
- check the connection between the motor and load.
- adapt the parameterization corresponding to the load.