Hakko Electronics Monitouch V9 Series Connection Manual page 70

Hide thumbs Also See for Monitouch V9 Series:
Table of Contents

Advertisement

1. Overview
1-58
$Pn
$s
(n = 1 to 8)
419-421
422-424
425-427
428-430
431-433
434-436
437-439
440-442
443-445
446-448
449
450
451
:
762
493
(PLC2)
763
494
(PLC2)
764
495
(PLC2)
:
800
500
(PLC3)
801
501
(PLC3)
802
502
(PLC3)
803
503
(PLC3)
804
504
(PLC3)
805
505
(PLC3)
:
765
508
(PLC2)
766
509
(PLC2)
767
510
(PLC2)
768
511
(PLC2)
*1
For PLC1, select [Yes] for [System memory ($s) V7 Compatible] under [Detail] on the [PLC Properties] window. The same information is
stored in the $P1 and $s.
*2
If designating the relay station number using $s130, select [Yes] for [System memory ($s) V7 Compatible] under [Detail] on the [PLC
Properties] window for PLC1. $P1: 004 cannot be used in this case.
*3
If executing device memory map control using $s762, $s763 and $s764, select yes for [System memory ($s) V7 Compatible] under [Detail]
on the [PLC Properties] window for PLC2. Note that $P2: 493/494/495 cannot be used in this case.
*1
-
Device memory map 21 Status, error code
-
Device memory map 22 Status, error code
-
Device memory map 23 Status, error code
-
Device memory map 24 Status, error code
-
Device memory map 25 Status, error code
-
Device memory map 26 Status, error code
-
Device memory map 27 Status, error code
-
Device memory map 28 Status, error code
-
Device memory map 29 Status, error code
-
Device memory map 30 Status, error code
-
Device memory map 31 Status
-
Device memory map 31 Error code 1
-
Device memory map 31 Error code 2
:
Device memory map reading prohibited flag (refer to the V9 Series Reference Manual).
0:
Periodical reading/synchronized reading executed
*3
Other than 0: Periodical reading/synchronized reading stopped
Forced execution of the device memory map TRL_READ/TBL_WRITE macro
Setting for macro operation when there is a station with a communication error
*3
0:
The macro is not executed in relation to any of the stations.
Other than 0: The macro is executed in relation to connected stations.
Device memory map writing prohibited flag (refer to the V9 Series Reference Manual).
0:
Periodical writing/synchronized writing executed
*3
Other than 0: Periodical writing/synchronized writing stopped
-
Device memory for Modbus slave communications
Used for setting the number of the reference device memory map and the device memory for
referring free area 31.Used for setting the number of the reference device memory map and the
device memory for referring free area 31.
$Pn500 to 505 are exclusively used for monitoring: $s800 to 805 are used for writing from the
Modbus master.
Refer to the Modbus Slave Communication Specifications.
:
Error response code (page 1-62)
If "800BH" (error code received) is stored for the error status ($Pn100 to 355), it is possible to
check the error code.
Contents
:
:
:
Device
Type
V
V
V
V