Parity - Hakko Electronics Monitouch V9 Series Connection Manual

Hide thumbs Also See for Monitouch V9 Series:
Table of Contents

Advertisement

16-8
16. Fuji Electric
NW0LA-RS2, NW0LA-RS4 (parameter setting)
On the PLC loader, set parameters for general communications.
Be sure to match the settings to those made under [Communication Setting] of the editor.
Item
Mode
Station No.
Initialize method
Baud rate

Parity

Data bits
Stop bits
Notes on use of 2-wire connection with NW0LA-RS4
The settings show above are not enough to establish a 2-wire connection with NW0LA-RS4.
To establish a connection, select [Initial file transfer] for [Initial Setting Mode] on the PLC loader, and select 2-wire
connection for [485 mode] in the initial setting file.
For more information, refer to the MICREX-SX SPB Series User's Manual <Communication Adapter> (FEH405).
Available Device Memory
The available setting range of device memory varies depending on the PLC model. Be sure to set within the range available for
the PLC to be used. Use [TYPE] when assigning indirect device memory for macro programs.
D
(data register)
W
(link register)
M
(internal relay)
L
(latch relay)
X
(input relay)
Y
(output relay)
R
(file register)
TN
(timer/current value)
CN
(counter/current value)
T
(timer/contact)
C
(counter/contact)
WS
(step relay)
General (Command asyn)
RS-232C: 0, RS-485: 0 to 31
Set parameters
4800 / 9600 / 19200 / 38400
Odd / Even / None
8 / 7
1 / 2
Standard Device Memory
Setting
TYPE
00H
01H
02H
WM as word device
03H
WL as word device
04H
WX as word device
05H
WY as word device
06H
07H
08H
09H
0AH
0BH
Remarks
These settings can also be specified for
the parameter area.
For more information, refer to the
MICREX-SX SPB Series User's Manual
<Communication Adapter> (FEH405).
Remarks