PLC_CTL
The macro command is the same as the one described in "16.1.4 MICREX-SX SPH/SPB Series (IEC Mode)".
16.1.6 MICREX-SX SPH/SPB CPU (IEC Mode)
Communication Setting
Editor
Communication setting
Connection Mode
Signal Level

Baud Rate

Data Length
Stop Bit
Parity
Target Port No.
PLC
No particular setting is necessary on the PLC.
Communication parameters are fixed to 38400 bps (baud rate), RS-422 (signal level), 8 bits (data length), 1 bit (stop bit), and
even (parity).
Available Device Memory
The available device memory is the same as the one described in "16.1.4 MICREX-SX SPH/SPB Series (IEC Mode)".
PLC_CTL
The macro command is the same as the one described in "16.1.4 MICREX-SX SPH/SPB Series (IEC Mode)".

16.1.7 MICREX-SX SPH/SPB CPU (N Mode / F Mode)

Communication Setting
The communication setting is the same as the one described in "16.1.6 MICREX-SX SPH/SPB CPU (IEC Mode)".
Available Device Memory
The available device memory is the same as the one described in "16.1.5 MICREX-SX SPH/SPB Series (N Mode / F Mode)".
PLC_CTL
The macro command is the same as the one described in "16.1.4 MICREX-SX SPH/SPB Series (IEC Mode)".
Item
1 : 1 / Multi-link2 / Multi-link2 (Ethernet)
Setting
RS-422/485
38400 bps
8 bits
1 bit
Even
0 to 31
16.1 PLC Connection
(Underlined setting: default)
Remarks
Do not change the setting from default.
16-13