Hakko Electronics Monitouch V9 Series Connection Manual page 134

Hide thumbs Also See for Monitouch V9 Series:
Table of Contents

Advertisement

MX200
Make the following settings on the front panel. For more information, refer to the PLC manual issued by the manufacturer.
LOAD connector
Communication Setup Mode
Item 0: Address setting
LOAD
connector
Item 1: Baud rate
setting
Item 2: Communication
mode
ASCII connector
Communication Setup Mode
Item 0: Baud rate
Item 1: Data length
Item 2: Parity bit
ASCII
connector
Item 3: Stop bit
setting
Item 4: Connector usage
Item 5: Connecting
device selection
Item 7: RTS control
Item 8: Signal level
selection
Station number
Make the following setting on the front panel.
MX Address Display/Setting Mode
Addr
Calendar
This model is equipped with a calendar function; however, the calendar data cannot be written from the V series. Thus, time
correction must be performed on the PLC side.
Available Device Memory
The available setting range of device memory varies depending on the PLC model. Be sure to set within the range available for
the PLC to be used. Use [TYPE] when assigning indirect device memory for macro programs.
R
(data register)
M
(auxiliary relay)
L
(latch relay)
X
(input relay)
Y
(output relay)
TP
(timer/current value)
TS
(timer/set value)
CP
(counter/current value)
CS
(counter/set value)
T
(timer/contact)
C
(counter/contact)
P
(link register)
1 to 63 (DEC): 1 to 63
7F(HEX): 127
48: 4800 bps
96: 9600 bps
192: 19200 bps
8E1: data length 8 bits, even parity, 1 stop bit
8n2: data length 8 bits, without parity, 2 stop bits
48: 4800 bps
96: 9600 bps
192: 19200 bps
7b: 7 bits
8b: 8 bits
EP: Even
oP: Odd
nP: None
1S: 1 bit
2S: 2 bits
Ldr: LOAD connector
CPL: Yamatake communication support device
non: No RTS control
232: RS-232C
1 to 63
Device Memory
Setting
Setting
Setting
TYPE
00H
R910, 929, 930, 956 to 987, 994 to 997: Read only
01H
M920 to 940, 970 to 990: Read only
02H
03H
04H
05H
Data format: BCD
06H
Data format: BCD
07H
Data format: BCD
08H
Data format: BCD
09H
0AH
0BH
4.1 PLC Connection
(Underlined setting: default)
Remarks
Settings can also be made in the
PLC application software.
For more information, refer to
the PLC manual issued by the
manufacturer.
(Underlined setting: default)
Remarks
Settings can also be made in the
PLC application software.
For more information, refer to the
PLC manual issued by the
manufacturer.
(Underlined setting: default)
Remarks
Remarks
4-3