7-2
7. CHINO
7.1.1
DP1000
Communication Setting
Editor
Communication setting
Item
Connection Mode
Signal Level
Baud Rate
Data Length
Stop Bit
Parity
Target Port No.
Digital Program Controller
DP1000
The communication parameters can be set using keys attached to the digital program controller.
Be sure to match the settings to those made under [Communication Setting] of the editor.
Mode No.
Mode 1
(Operation status
selection)
Mode 8
(Communication
setting)
* To start program operation from the V series, select "MASTER COM." for program start method. To select a pattern number from the V
series, select "COM" for pattern selection method.
1 : 1 / 1 : n / Multi-link2 / Multi-link2 (Ethernet) /
1 : n Multi-link2 (Ethernet)
RS-232C / RS-422/485
4800 / 9600 / 19200 / 38400 bps
None / Odd / Even
Item
*
MASTER COM.: Start by communication
Program start method
*
COM: Selection by communication
Pattern selection method
Communication function,
COM: Host communication
type
Device No.
01 to 99
Baud rate
4800 / 9600 bps
Communication characters
Data length: 7 / 8 bits
(Data length, parity,
Parity: Even / Odd / None
stop bit)
Stop bit: 1 / 2 bits
Setting
7 / 8 bits
1 / 2 bits
1 to 99
Setting
(Underlined setting: default)
Remarks
(Underlined setting: default)
Remarks
Invalid during RS-232C
communication
00: Communication not
possible