Hakko Electronics Monitouch V9 Series Connection Manual page 292

Hide thumbs Also See for Monitouch V9 Series:
Table of Contents

Advertisement

Address
F-MPC04/F-MPC04P/F-MPC04S
12zz
OCG operation time
13zz
Load pre-alarm sensitivity current
14zz
Load pre-alarm operation time
15zz
Automatic display circuit register
16zz
ZCT select
17zz
VT select
18zz
19zz
20zz
Phase selection
21zz
Power alarm upper limit
22zz
Integral power pulse multiplying factor
23zz
Load pre-alarm operation value
24zz
Load pre-alarm operation time
25zz
Leak pre-alarm sensitivity current
26zz
Leak pre-alarm operation time
27zz
OCG sensitivity current
28zz
OCG operation time
29zz
Operation type for power
30zz
31zz
32zz
33zz
34zz
35zz
36zz
37zz
38zz
39zz
40zz
41zz
42zz
43zz
44zz
45zz
46zz
16.2 Temperature Controller/Servo/Inverter Connection
*2
(Blank)
(Blank)
Power alarm upper limit
Pulse multiplying factor
*4
*4
Load pre-alarm
operation value
Leak pre-alarm
sensitivity current
Leak pre-alarm
*2
operation time
Leak alarm sensitivity
current
Leak alarm operation
*2
time
Operation type for
power
(Blank)
Phase R input position
History of turning
(Blank)
breaker ON
Show/hide cause of
(Blank)
trouble
Phase interruption
(Blank)
alarm of neutral line
(Blank)
Alarm output 1
(Blank)
Alarm output 2
(Blank)
Contact input 1
(Blank)
Contact input 2
(Blank)
(Blank)
Rated current (IN)
(Blank)
Current demand time
(Blank)
Voltage demand time
(Blank)
Power demand time
(Blank)
Leak demand time
(Blank)
(Blank)
(Blank)
FePSU
F-MPC30/F-MPC50/F-MPC55V/F-MPC60B
(Blank)
Protective OC (output setting)
Protective OCA overcurrent pre-alarm
(Blank)
(current setting)
Protective OCA overcurrent pre-alarm
(Blank)
(operation time)
Protective OCA overcurrent pre-alarm
(Blank)
(output setting)
(Blank)
Protective OCG (51G) (current setting)
(Blank)
Protective OCG (51G) (characteristic)
(Blank)
Protective OCG (51G) (time magnification)
(Blank)
Protective OCG (51G) (output setting)
(Blank)
Protective OCG (50G) (current setting)
Protective OCG (50G) (operation time)
Protective OCG (50G) (output setting)
Protective DG (DG/OCG) (current setting)
(Blank)
Protective DG (DG/OCG) (operation time)
Protect DG (DG/OCG) (output setting)
Protective DG (DG/OCG) (maximum
*2
sensitivity phase angle)
Protective DG (DG/OCG) (voltage setting)
Protective DG (DG/OCG) (selected from DG
*2
or OCG)
Protective 0 V (voltage setting)
Protective 0 V (operation time)
Protective 0 V (output setting)
Protective UV (voltage setting)
Protective UV (operation time)
Protective UV (output setting)
Protective UV2 (voltage setting)
Protective UV2 (operation time)
Protective UV2 (output setting)
(Blank)
Protective UV operation setting
Voltage establishment VR (voltage setting)
Voltage establishment VR (operation time)
Voltage establishment VR (output setting)
Protective OVG (voltage setting)
Protective OVG (operation time)
(Blank)
Protective OVG (output setting)
(Blank)
ZPD/EVT selection
(Blank)
Phase interruption relay
16-39
*3
*2
*2
*2
*3
*3
*2
*2
*2
*2
*2
*2