16.2.23 FALDIC- Series
Communication Setting
Editor
Communication setting
Item
Connection Mode
Signal Level
Baud Rate
Data Length
Stop Bit
Parity
Target Port No.
Servo Amplifier
Set the communication parameters using the touch panel mounted on the servo amplifier.
Be sure to match the settings to those made under [Communication Setting] of the editor.
System parameter
*1
The communication function of the servo amplifier can be selected at the time of purchase. Select a model on which host interface:
universal communication (RS-485) is available.
*2
The following communication parameters are fixed; data length: 8 bits, stop bit: 1 bit, and parity: even.
Available Device Memory
The available setting range of device memory varies depending on the model. Be sure to set within the range available for the
model to be used. Use [TYPE] when assigning indirect device memory for macro programs.
00
(monitor data)
01
(data on positioning being executed)
10
(sequence mode)
11
(control input/output signal)
12
(alarm detection log)
13
(detected alarm contents)
20
(standard parameter)
21
(system parameter)
30
(positioning data)
40
(control command)
*1
Input a parameter number by manual operation.
*2
Address denotations XXYY
Setting
1 : 1 / 1 : n / Multi-link2 /
Multi-link2 (Ethernet) /
1 : n Multi-link2 (Ethernet)
RS-422/485
9600 / 19200 / 38400 bps
1 to 31
Parameter
(No. 96)
(No. 97)
Device Memory
Address
Positioning data number (01H - 63H)
16.2 Temperature Controller/Servo/Inverter Connection
Do not change the default setting other than baud rate because
8 bits
the setting on the servo amplifier cannot be changed.
1 bit
Even
Item
Station number
Baud rate
TYPE
00H
Double-word, read only
01H
Double-word, read only
02H
Read only
03H
Read only
04H
Read only
05H
Read only
*1
06H
Double-word
*1
07H
Double-word
*2
08H
Double-word
09H
Double-word, write only
(Underlined setting: default)
Remarks
(Underlined setting: default)
Setting
1 to 31
0: 9600 bps
1: 19200 bps
2: 38400 bps
Remarks
16-69
Example
1
0

Hide quick links: