5.9.9. General Endurance Menu

This menu performs the general endurance running.
You can operate various driving systems according to your desired settings.
The available settings are shown below.
Setup item
Operation speed (CW,
CCW)
Media feed amount
Number of endurance
running cycles
Notes :
If the number of endurance running cycles is set to -1, the units continuously repeat
endurance running until a key input is given from the operation panel.
The maximum counter value for endurance running cycles is 99999999 (up to 8-digit
number). If the number of cycles exceeds the maximum value, the counter is reset to 0.
* Speed CW *
Speed
* Speed CCW *
Speed
* Feed Amount *
* Life Count *
Count
* Total Life *
Count
* Total Life *
End
Description
Sets carriage operation speed (CW
and CCW).
Set the media feed amount per cycle
Set the number of endurance running
cycles
240 / 300 +
240 cps -
↓ ENTER
240 / 300 +
240 cps -
↓ ENTER
0 – 100.0 mm +
0.1 mm -
↓ ENTER
-1 → 10000 +
↓ ENTER
↓ ENTER or CANCEL
196
Parameters
240/300
0 to 100
-1 to 10000
Speed (CW)
Speed (CCW)
Media feed amount
Number of total endurance running cycles
50 -
5
Perform endurance running
50
Spitfire – Maintenance Manual
Remarks
Unit: cps
Unit: mm
AP-74096, Rev. 1.0, 09/06/05