4. O-rings cannot be reused. Always replace with new
ones.
5. Be sure to apply new compressor oil to the O-rings
when connecting lines.
6. Be sure to install the sensor and the insulator on the
place where they were before.
Refrigerant Line and Associated Parts
Legend
(1) Clip and Clamp
(2) Liquid Line (High-Pressure Pipe)
HEATING, VENTILATION AND AIR CONDITIONING (HVAC) 1A–61
7. To install a new evaporator core, add 50cc (1.7 fl. oz.)
8. Tighten the refrigerant lines to the specified torque.
9. Apply an adhesive to the parting face of the lining
Refrigerant Line
(3) Discharge Line (High-Pressure Hose)
(4) Radiator Grille
(5) Suction Line (Low-Pressure Pipe)
of new compressor oil to the new core.
Refer to Main Data and Specifications for Torque
Specifications in this section.
when assembling the evaporator assembly.
852RX001