AUTOMATIC TRANSAXLE [AW6A-EL, AW6AX-EL]
TCM INSPECTION[AW6A-EL, AW6AX-EL]
TR Switch Operating Inspection
1. Verify that the starter operates only when the ignition switch is turned to the START position with the selector
lever in P or N position.
• If there is any malfunction, neutral position learning. (See 05-17-25 TCM REMOVAL/
INSTALLATION[AW6A-EL, AW6AX-EL].)
2. Verify that the back-up lights illuminate when shifted to R position with the ignition switch at the ON position.
• If there is any malfunction, neutral position learning. (See 05-17-25 TCM REMOVAL/
INSTALLATION[AW6A-EL, AW6AX-EL].)
3. Verify that the positions of the selector lever and
the indicator light correspond.
• If there is any malfunction, perform the neutral
position learning. (See 05-17-25 TCM
REMOVAL/INSTALLATION[AW6A-EL,
AW6AX-EL].)
4. Verify that the TR PID is normal.
• If there is any malfunction, perform the neutral
position learning. (See 05-17-25 TCM
REMOVAL/INSTALLATION[AW6A-EL,
AW6AX-EL].)
Control Module Inspection
1. Remove the air cleaner component. (See 01-13-5 INTAKE AIR SYSTEM REMOVAL/INSTALLATION[L3 WITH
TC].)
2. Measure the voltage at each TCM connector (wiring harness-side) terminal and refer to the terminal voltage
table.
• If the voltage is not as specified in the Terminal Voltage Table (Reference), inspect the parts under
"Inspection item (s)".
Warning
• Be careful not to damage the connector waterproofing when measuring the TCM terminal voltage.
If damaged, the waterproofing efficiency could be negatively affected.
Note
• Use the ground of terminal A9 of the TCM connector (wiring harness-side) when measuring terminal
voltage, as an error may occur when connecting the negative circuit tester to ground.
Terminal Voltage Table (Reference)
Terminal
Signal
Battery back up
A1
supply
Up switch
A3
(Selector lever
component)
TCM SHORT CORD CONNECTOR (TCM SIDE)
A8 A7 A6 A5 A4 A3
A16 A15 A14 A13 A12 A11
Connected to
Test condition
Battery
Constant
Shift up
(M range)
Up switch
(Selector lever
Other ranges, all
component)
positions
SELECTOR INDICATOR LIGHT
A2 A1
A10 A9
Voltage (V)
• Inspect battery
B+
• Inspect related harness
• Inspect selector lever
Below 1.0
component
(See 05-18-6 SELECTOR
LEVER COMPONENT
B+
INSPECTION)
• Inspect related harness
id051723800300
acxuuw00000412
acxuuw00000521
Inspection item (s)
05-17–21