4. Measure the resistance between the following
terminals.
• If not as specified, inspect the ground, then
perform the operating inspection.
ATF temperature: 40150 ° ° ° ° C {40302 ° ° ° ° F}
Terminal
Solenoid valve
AGND
Shift solenoid A
CGND
Shift solenoid B
GGND
Shift solenoid C
BGND
Shift solenoid D
FGND
Shift solenoid E
DI
Pressure control
5. Connect the transale connector.
6. Install the air cleaner component. (See
7. Connect the negative battery cable.
Operating Inspection
1. Disconnect the transale connector.
Caution
• • • • Do not apply battery position voltage to terminals A, B, C, D, F and G for more than three seconds.
Note
• Because the operation sound of the valves is small, perform inspection in a quiet place.
2. Apply battery positive voltage to terminals A,B,C, F or G and battery negative voltage to GND, and verify that
operating sound is heard from solenoid.
• If the "click" is not heard, inspect the transale harness.
If the transale harness is okay, perform the resistance inspection (off-vehicle inspection).
If there is a problem, repair or replace the transale harness.
3. Apply battery positive voltage to terminal D and
battery negative voltage to terminal I, and verify
that operating sound is heard from solenoid.
• If the "click" is not heard, inspect the transale
harness.
If transale harness is okay, perform the
resistance inspection (off-vehicle
inspection)
If there is a problem, repair or replace the
transale harness.
Resistance Inspection (Off-Vehicle Inspection)
1. Remove the control valve body. (See
2. Measure the resistance of each solenoid valve individually.
• If not as specified, replace the solenoid valve.
3. Install the control valve body. (See
AUTOMATIC TRANSAXLE
Resistance
(ohm)
1.04.2
1.04.2
1.04.2
10.926.2
10.926.2
2.47.3
F10 INTAKE-AIR SYSTEM
K28 SOLENOID VALVE
K28 SOLENOID VALVE
REMOVAL/INSTALLATION.)
REMOVAL/INSTALLATION.)
REMOVAL/INSTALLATION.)
A6E5614W039
K
A6E5614W040
K27