2) Measure voltage at output terminal D and
ground terminal E when the yaw rate
sensor is rotated left and right.
Caution
• • • • Be careful when turning the yaw rate
sensor rotation position while it is in a
reversed state because the rotation
direction and voltage will be reversed.
Voltage
Right rotation:
fluctuation between 2.54.62 V
Left rotation:
fluctuation between 2.50.33 V
COMBINE SENSOR INITIALIZATION PROCEDURE
End Of Sie
1. Set the SST (WDS or equivalent) to the DLC-2
2. Access the active command mode and select the
YAWRATE, then follow the indication on the
monitor.
3. Select the LATACCEL and follow the indication
on the monitor.
STEERING ANGLE SENSOR REMOVAL/INSTALLATION
End Of Sie
1. (See
T38 COMBINATION SWITCH
STEERING ANGLE SENSOR INSPECTION
End Of Sie
1. (See
T39 STEERING ANGLE SENSOR
End Of Sie
DSC OFF SWITCH REMOVAL/INSTALLATION
1. (See
P31 TCS (DSC) OFF SWITCH
DSC OFF SWITCH INSPECTION
End Of Sie
1. (See
P32 TCS (DSC) OFF SWITCH
End Of Sie
P44
DYNAMIC STABILITY CONTROL
DISASSEMBLY/ASSEMBLY.)
INSPECTION.)
REMOVAL/INSTALLATION.)