Validating The Csv File; Adding And Importing Multiple Infranet Controllers - Juniper NETWORK AND SECURITY MANAGER 2010.4 - CONFIGURING INFRANET CONTROLLER GUIDE REV 01 Manual

Configuring infranet controllers guide
Hide thumbs Also See for NETWORK AND SECURITY MANAGER 2010.4 - CONFIGURING INFRANET CONTROLLER GUIDE REV 01:
Table of Contents

Advertisement

NSM Infranet Controller Configuration Guide

Validating the CSV File

Adding and Importing Multiple Infranet Controllers

18
When you add the Infranet Controllers, NSM validates the configuration information in
the .csv file and creates a validation report. The report lists any incorrect or duplicate
configurations, and indicates the exact line that contains invalid data.
NOTE: The validation report displays only the first error in the line. If the line
contains additional errors, those errors do not appear in the validation report.
Select Cancel to quit adding multiple Infranet Controllers, or select Add Valid Devices
to begin adding the Infranet Controllers for which you have provided valid device
configurations.
If the validation report listed incorrect configurations, you can still select Add Valid
Devices; however, only the devices with correct configurations are added. If the .csv file
contains duplicate configurations, NSM ignores the duplicates.
After you have added multiple Infranet Controllers, you cannot roll back or undo your
changes. To edit or delete Infranet Controllers, select the Infranet Controller in the NSM
UI and make the necessary changes.
To add and import multiple Infranet Controllers in the NSM UI:
From the left pane of the NSM UI, click Configure.
1.
Expand Device Manager and select Devices. The Devices workspace appears on the
2.
right side of the screen.
Click the Device Tree tab, click the New button, and select Many Devices. The
3.
New-Device dialog box appears.
In the New-Device dialog box:
4.
Select Device is Not Reachable.
Specify the location of the CSV file.
Specify the output directory for the .cli file. For each valid device configuration that
uses a dynamic IP address, NSM creates a .cli output file. By default, the .cli file is
saved to the following GUI server directory:
/usr/netscreen/GuiSvr/var/ManyDevicesOutput/<inputFile_YYYYMMDDHHMM>/
Before the Infranet Controllers can be managed by NSM, you must enter the CLI
commands in the .cli file on the physical security device.
Click Next. The Add Device wizard validates the CSV file and provides a validation
5.
report.
Select Cancel to quit the Add Many Devices process.
Copyright © 2010, Juniper Networks, Inc.

Advertisement

Table of Contents
loading

Table of Contents