Disassociating the Configuration Between an Enforcement Point and an Infranet

Controller

Copyright © 2010, Juniper Networks, Inc.
Select the Location Group the enforcement points must belong to in the selected
7.
Infranet Controller. Each enforcement point can be associated with only one Location
Group available in the Infranet Controller.
Enter the Infranet Controller port number to which the enforcement point should
8.
communicate. The default port is 1812.
Enter the IP address that should be used for RADIUS communication. If you do not
9.
specify an address, the enforcement point's management IP address is used by default.
You have the option to select the IP address of the RADIUS communication server
only if you select a single enforcement point because the IP address to communicate
with an Infranet Controller is unique.
Select Use Load Balancer with IP Address if the Infranet Controller is load balancer
10.
administered. The IP address of the Load Balancer is then used as the Radius Server
in the EX-series switch configuration.
Select Run "Update Device" task to push configuration changes on both the Infranet
11.
Controller and enforcement points. The configuration status of the enforcement points
changes to Managed, InSync.
Select Run "Summarize Delta Config" task to ensure the association between the
12.
Infranet Controller and enforcement point in the application database. The
configuration status of these devices becomes Managed, NSM Changed.
Click OK. The selected enforcement points are listed under the associated Infranet
13.
Controller.
Enabling Dot1x Ports on the Enforcement Points Using the UAC Manager on page 184
Disassociating the Configuration Between an Enforcement Point and an Infranet
Controller on page 183
Disabling the Dot1x Ports on an Enforcement Point Using the UAC Manager on page 185
UAC Manager in NSM Overview on page 181
To disassociate enforcement points from an Infranet Controller:
In the NSM navigation tree, select UAC Manager > Infranet Controller. The Infranet
1.
Controller workspace appears.
Select the Infranet Controller and the Ex-series switch that needs to be disassociated.
2.
Click the Delete Enforcement Point button. The Disassociate Enforcement Points
3.
dialog box appears with the list of enforcement points to be deleted.
Select Run "Update Device" task to push configuration changes on both the Infranet
4.
Controller and enforcement points. The configuration status of the enforcement points
changes to Managed, InSync.