Juniper NETWORK AND SECURITY MANAGER 2010.4 - CONFIGURING INFRANET CONTROLLER GUIDE REV 01 Manual page 32

Configuring infranet controllers guide
Hide thumbs Also See for NETWORK AND SECURITY MANAGER 2010.4 - CONFIGURING INFRANET CONTROLLER GUIDE REV 01:
Table of Contents

Advertisement

NSM Infranet Controller Configuration Guide
Confirming Connectivity and Importing the Infranet Controller Device Configuration
Related
Documentation
14
Enter the unique external ID provided by the NSM administrator in the Device ID box.
5.
Enter the first connection one-time password provided by the NSM administrator in
6.
the HMAC Key box.
Click Enable to activate the DMI agent.
7.
Click Save Changes, and the device attempts to establish a session with the NSM
8.
application.
The device software initiates the TCP connection to NSM and identifies itself using the
specified device ID and HMAC. Both sides then engage in SSH Transport Layer interactions
to set up an encrypted tunnel. The NSM application authenticates itself to the Infranet
Controller based on the username and password.
In NSM, validate connectivity with the device, and then import the device configuration:
From the Devices workspace, select the Device List tab.
1.
Check the newly added device in the Connection Status column. The connection
2.
status must change from Never Connected to Up.
If the connection status appears as Device Platform Mismatch or Device Firmware
Mismatch, delete the device from the application and add it back using the correct device
platform and managed OS, respectively.
To import the device configuration:
From the Devices workspace, select the Device List tab.
1.
Right-click the newly added Infranet Controller device and select Import Device. The
2.
Save Changes dialog box appears.
If you are prompted to save policy or VPN changes, click Yes. The Device Import Option
3.
dialog box appears.
Select Run Summarize Delta Config, and click OK and Yes. The Job Information dialog
4.
box displays the progress of the delta config summary. You can also monitor the
progress in Job Manager.
The next step is to verify the imported configuration using either the Device Monitor
or the Device Manager in NSM. See "Verifying Imported Device Configurations (NSM
Procedure)" for details.
Importing an Infranet Controller Through Reachable Workflow on page 15
Creating and Applying an Infranet Controller Template on page 29
Verifying Imported Device Configurations on page 19
Copyright © 2010, Juniper Networks, Inc.

Advertisement

Table of Contents
loading

Table of Contents