Enabling Or Disabling The Connection To An Existing Idp Device - Juniper NETWORK AND SECURITY MANAGER 2010.4 - CONFIGURING INFRANET CONTROLLER GUIDE REV 01 Manual

Configuring infranet controllers guide
Hide thumbs Also See for NETWORK AND SECURITY MANAGER 2010.4 - CONFIGURING INFRANET CONTROLLER GUIDE REV 01:
Table of Contents

Advertisement

Enabling or Disabling the Connection to an Existing IDP Device

Copyright © 2010, Juniper Networks, Inc.
Cancel—Cancels the modifications.
Table 56: New IDP Device Entry Configuration Details
Option
Function
Name
Specifies the name used to identify the
new connection entry.
Hostname
Specifies the hostname or IP address of
the IDP device to which the Infranet
Controller connects to receive application
and resource attack alert messages.
TCP Port
Specifies the TCP port on the IDP device
to which the Infranet Controller listens
when receiving application and resource
attack alert messages.
One Time
Specifies the encrypted password the
Password
Infranet Controller uses when conducting
the initial Transport Layer Security (TLS)
handshake with the IDP device.
Addresses to
Reports attack information only for the
monitor
specified IP addresses.
Severity
Specifies the severity level, which is a
Filter
number on a scale from 1 to 5, where 1 is
informational and 5 is critical.
To enable or disable existing IDP device entries on the Infranet Controller:
In the NSM navigation tree, select Device Manager > Devices.
1.
Click the Device Tree tab, and then double-click the Infranet Controller device on
2.
which you want to enable or disable the IDP device.
Click the Configuration tab. In the configuration tree, select System > Configuration
3.
> Sensors.
Select the Sensors tab. The corresponding workspace appears.
4.
Click the IDP device entry you want to enable or disable.
5.
From the IDP device workspace, select the Enable/Disable Sensor option.
6.
Click one:
7.
Chapter 18: Configuring the Infranet Controller to Interoperate with IDP
Your Action
Enter a name for the new connection
entry.
Enter the hostname or IP address.
Enter the TCP port number.
Enter the encrypted Infranet
Controller OTP password as
displayed on the IDP ACM
configuration summary screen.
NOTE: The hostname, TCP port, and
one-time password must already be
configured on the IDP device before
this configuration can be successful.
Enter the individual IP addresses and
address ranges, one entry per line.
Enter the subnet address in network
format 0.0.0.0/0.
Select a severity level between 1 and
5.
195

Advertisement

Table of Contents
loading

Table of Contents