Recall Safe - Yamaha CS1D Operating Manual

Digital audio mixing system software v1.41
Hide thumbs Also See for CS1D:
Table of Contents

Advertisement

RECALL SAFE

[Function]
Select the channels, parameters, or units that you wish to set to Recall Safe (a state of being excluded from
Recall operations). For example if you have specified Recall Safe for a channel that you always want to operate
manually, the parameters of that channel will not change even if you recall a new scene.
Console
In the LCD FUNCTION
ACCESS block, press the
[SCENE] switch (press repeat-
edly until the screen shown at the
right appears)
Display
MENU button
SCENE button
RECALL SAFE tab
[Screen functions]
1
1 SAFE ON/OFF buttons
These buttons turn Recall Safe on/off for each chan-
nel. This can be set for the following channels.
CH 1–96 {1-48} ........Input channels 1–96 {1–48}
ST IN 1–8 {1–4}........ST IN channels 1–8 {1–4}
MIX 1–48..................MIX channels 1–48
MTRX 1–24 ..............MATRIX channels 1–24
ST A/B.......................STEREO A/B channels
Hint
Recall Safe on/off settings are also shown by the
RECALL SAFE LED on the control panel, and in the
INPUT CHANNEL VIEW screen and OUTPUT
CHANNEL VIEW screen.
2
2 SAFE PARAMETER SELECT buttons
For each channel, select the parameters that you wish
to set to Recall Safe. The following parameters can be
selected.
ALL ..................All parameters of that channel
ATT..................The ATT parameter of that channel
EQ....................The EQ parameters of that channel
(except ATT)
FADER ............The fader of that channel (includes
BALANCE for STEREO A/B)
SEND/TO MTRX .... The SEND/TO MATRIX
parameters of that channel
(ON, LEVEL, PAN, PRE/
POST, PAN, PRE POINT)
UNIT ........................ The parameters of the unit
patched to that channel (HA
GAIN GANG and HA A/B
LINK are included in ALL)
Simply turning on the above buttons does not enable
the Recall Safe function. To enable Recall Safe, you
must turn on the SAFE ON/OFF button (1) for the
corresponding channel.
However, Unit Recall Safe is independent of Channel
Recall Safe. For this reason, simply turning on the
UNIT button will exclude the corresponding unit
from recall operations even if the SAFE ON/OFF
button is off.
SCENE functions
23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pm1d

Table of Contents