23 FUNCTIONS LINKED WITH A VEHICLE
23.2 Controlling Car Behavior by Linking with the Horn Alert Port State (Horn Alert)
Also, the Horn Alert port is activated according to the Horn Alert Logic Signal configuration when the transceiver receives
Status No. 89 regardless of the above conditions, Optional Signaling configuration, and other configurations relevant to
Horn Alert.
 If Horn Alert is configured for neither the Horn Alert key nor Menu Mode:
Horn Alert is activated under the following conditions:
If the received Group ID matches the Group ID preconfigured for the transceiver while "None" is configured for
Optional Signaling of the preconfigured Group ID and Horn Alert is enabled as well.
If the received Group ID and Optional Signaling match the Group ID and Optional Signaling preconfigured for
the transceiver, while "DTMF" or "FleetSync" is configured for Optional Signaling of the preconfigured Group
ID and Horn Alert is enabled as well. However, "FleetSync" must be configured for Optional Signaling to make
a Paging Call.
If the Fix ID with Horn Alert enabled matches the received Group ID.
Also, the Horn Alert port is activated according to the Horn Alert Logic Signal configuration when the transceiver
receives Status No. 89 regardless of the above conditions, Optional Signaling configuration, and other configurations
relevant to Horn Alert.
Configuration using KPG-111D/ DN
Configuring the Horn Alert to be enabled or disabled for each Group ID (
Configuring the Horn Alert (Fix ID) to be enabled or disabled (
NXDN Trunking System
One of the following conditions must be satisfied to activate the Horn Alert in an NXDN Trunking system:
If Horn Alert is enabled by pressing the Horn Alert key or selecting "Horn Alert" from Menu Mode
If "Start Up" is configured for Horn Alert Mode using KPG-111D/ DN
If one of the above conditions is satisfied, Horn Alert is activated when the transceiver receives an Individual Call, Paging
Call or Telephone Call.
Also, the Horn Alert port will be activated according to the configuration for Horn Alert Logic Signal when the transceiver
receives Horn Alert Status regardless of the above conditions and other configurations relevant to Horn Alert.
Note
Horn Alert Status can be configured using KPG-111D/ DN. (
Horn Alert Logic Signal
Horn Alert Logic Signal is a function to activate Horn Alert port, depending on the configuration, upon activation of Horn
Alert.
How the Horn Alert port is activated when Horn Alert is activated can be configured using KPG-111D/ DN.
Configuration
Until Reset
The Horn Alert port remains active until the matching status of Optional Signaling is reset.
1 s to 30 s
The Horn Alert port remains active for configured amount of time.
The Horn Alert port is activated 3 times at 500 ms intervals. (Refer to
Pulse
Only if the transceiver receives Fix ID, the Horn Alert port is activated for 1 sec and deactivated for 500 ms, and then
it is activated for 1 sec again. (Refer to
FUNC (K)/Ver 4.00
See
See
FRPG 8.19.9 Status Tab)
Table 23-2 Horn Alert Logic Signal
Description
Figure 23-2 Pulse 2 on page
See
FPRG 8.7.11 Horn Alert)
FPRG 8.6.20 Horn Alert (Fix ID))
Figure 23-1 Pulse 1 on page
496.)